1. When the kettle body is transported and installed in place, avoid touching the magnetic stirrer on the top of the kettle lid. The reactor operation room requires good ventilation and meets explosion-proof requirements. Install the unit on the bracket and level it with the inclined iron on the four supports to keep the equipment perpendicular to the ground. Anti-static grounding devices should be installed on the flammable and explosive equipment of the reaction medium to eliminate static electricity.

2. Select matching gaskets according to the reactor medium, design pressure and design temperature. Sealing gasket shall be installed between the kettle body and the kettle lid, the magnetic stirrer and the kettle lid, and the flanges of each pipe, and the bolts shall be tightened again. When tightening the bolts, the bolts should be tightened evenly according to the diagonal distribution principle, and should be tightened 2-3 times to prevent the bolts from being deflected and the sealing gaskets from affecting the sealing effect.

3. The fuel tank of the reducer should be added with No. 13 compressor oil or No. 11 cylinder oil. The oil level should be added to the specified mark and the oil should be replaced regularly.

4. If it is a high-temperature, high-speed magnetic stirrer, add lubricating oil to the bearing oil filling port before use. Regularly add lubricating oil from the oil filling hole in the future use.

  

Sales Minister Tan Xuezhou welcomes your inquiry! Welcome to visit our company!


Forensic Reagent Kits

YESU Y41SE Fluorescent Detection Kit

1. The six-color fluorescence detection platform amplified 40 Y chromosome STR loci simultaneously, including 33 low mutation rate STR loci (mutation rate less than 1%) and 7 fast mutation loci (mutation rate more than 1%), a very low mutation rate Y INDEl
2. Y-str database is suitable for male pedigree screening and has strong individual identification ability. It contains all 35 loci which are required and preferred in Y database construction criteria.
3. Contains 12 mini-STR(loci with amplified length less than 220bp) to obtain more information from DNA degradation materials.
4, material compatibility, compatible with the direct amplification of most materials and the amplification of purified DNA
5. Rapid amplification, the theoretical amplification time was about 70 minutes.

Forensic Reagent Kits,Fluorescent Detection Kit,Y-Str Reagent Kit,Forensic Dna Identification Kits

Nanjing Superyears Gene Technology Co., Ltd. , https://www.superyearsglobal.com

Posted on